研究業績(2012年)
英文原著論文・英文総説
- Optimization of the X-ray monitoring angle for creating a correlation model between internal and external respiratory signals. Akimoto M, Nakamura M, Mukumoto N, Yamada M, Ueki N, Matsuo Y, Sawada A, Mizowaki T, Kokubo M, Hiraoka M. Med. Phys., 39(10), 6309~6315, 2012
- Positional accuracy of novel x-ray-image-based dynamic tumor-tracking irradiation using a gimbaled MV x-ray head of a Vero4DRT (MHI-TM2000). Mukumoto N, Nakamura M, Sawada A, Takahashi K, Miyabe Y, Takayama K, Mizowaki T, Kokubo M, Hiraoka M. Med. Phys., 39(10), 6287~6296, 2012
- Dosimetric evaluation of the impacts of different heterogeneity correction algorithms on target doses in stereotactic body radiation therapy for lung tumors. Narabayashi M, Mizowaki T, Matsuo Y, Nakamura M, Takayama K, Norihisa Y, Sakanaka K, Hiraoka M. J. Radiat. Res., 53(5), 777~784, 2012
- Analysis of dosimetric parameters associated with acute gastrointestinal toxicity and upper gastrointestinal bleeding in locally advanced pancreatic cancer patients treated with gemcitabine-based concurrent chemoradiotherapy. Nakamura A, Shibuya K, Matsuo Y, Nakamura M, Shiinoki T, Mizowaki T, Hiraoka M. Int. J. Radiat. Oncol. Biol. Phys., 84(2), 369~375, 2012
- Dose-volume metrics associated with symptomatic radiation pneumonitis after stereotactic body radiation therapy for lung cancer. Matsuo Y, Shibuya K, Nakamura M, Narabayashi M, Sakanaka K, Ueki N, Miyagi K, Norihisa Y, Mizowaki T, Nagata Y, Hiraoka M. Int. J. Radiat. Oncol. Biol. Phys., 83(4), e545~e549, 2012
- Dosimetric investigation of breath-hold intensity-modulated radiotherapy for pancreatic cancer. Nakamura M, Kishimoto S, Iwamura K, Shiinoki T, Nakamura A, Matsuo Y, Shibuya K, Hiraoka M. Med. Phys., 39(1), 48~54, 2012
- Experimental validation of heterogeneity-corrected dose-volume prescription on respiratory-averaged CT images in stereotactic body radiotherapy for moving tumors. Nakamura M, Miyabe Y, Matsuo Y, Kamomae T, Nakata M, Yano S, Sawada A, Mizowaki T, Hiraoka M. Med. Dosim., 37(1), 20~25, 2012
- Interfractional dose variations in intensity-modulated radiotherapy with breath-hold for pancreatic cancer. Nakamura M, Shibuya K, Nakamura A, Shiinoki T, Matsuo Y, Nakata M, Sawada A, Mizowaki T, Hiraoka M. Int. J. Radiat. Oncol. Biol. Phys., 82(5), 1619~1626, 2012
和文原著論文・和文総説
- Vero4DRT (MHI-TM2000)を用いた動体追尾照射の臨床適用.中村光宏. Rad Fan, 10(3), 11~14, 2012
国際学会発表
- Estimation of a tracking margin in surrogate signal-based dynamic tumor tracking irradiation with Vero4DRT(MHI-TM2000). Nakamura M, Mukumoto N, Ueki N, Akimoto M, Yamada M, Matsuo Y, Mizowaki T, Sawada A, Kokubo M, Hiraoka M. 54th ASTRO annual meeting
- Intra-fractional Tracking Accuracy in Surrogate Signal-based Dynamic Tumor-tracking Irradiation with Vero4DRT (MHI-TM2000). Mukumoto N, Nakamura M, Sawada A, Yamada M, Takahashi K, Miyabe Y, Matsuo Y, Mizowaki T, Kokubo M, Hiraoka M. 54th ASTRO annual meeting
- Four-dimensional Monte Carlo Dose Calculation Method for Dynamic Tumor Tracking Irradiation With a Gimbaled X-ray Head. Ishihara Y, Sawada A, Miyabe Y, Mukumoto N, Nakamura M, Ueki N, Matsuo Y, Mizowaki T, Kokubo M, Hiraoka M. 54th ASTRO annual meeting
- Improvement of Tracking Accuracy With 4DRT Using Phase Shift Correction. Akimoto M, Nakamura M, Mukumoto N, Yamada M, Takahashi K, Matsuo Y, Mizowaki T, Sawada A, Kokubo M, Hiraoka M. 54th ASTRO annual meeting
- Quality assurance of the surrogate signal-based dynamic tumor-tracking irradiation with Vero4DRT (MHI-TM2000). Mukumoto N, Nakamura M, Sawada A, Suzuki Y, Takahashi K, Miyabe Y, Kaneko S, Mizowaki T, Kokubo M, Hiraoka M. 54th AAPM annual meeting
- Determination of the Optimal X-Ray Monitoring Angle for Creating a Correlation Model in Dynamic Tumor Tracking Irradiation with Vero4DRT(MHI-TM2000). Akimoto M, Nakamura M, Mukumoto N, Yamada M, Ueki N, Matsuo Y, Sawada A, Mizowaki T, Kokubo M, Hiraoka M. 54th AAPM annual meeting
- Dosimetric investigation of breath-hold intensity-modulated radiotherapy for pancreatic cancer. Nakamura M, Kishimoto S, Iwamura K, Shiinoki T, Nakamura A, Matsuo Y, Shibuya K, Hiraoka M. The World Congress on Medical Physics and Biomedical Engineering 2012
- Development of four-dimensional Monte Carlo dose calculation system for tumor-tracking irradiation with a gimbaled X-ray head. Ishihara Y, Sawada A, Miyabe Y, Mukumoto N, Nakamura M, Ueki N, Matsuo Y, Mizowaki T, Kokubo M, Hiraoka M. The World Congress on Medical Physics and Biomedical Engineering 2012
招待講演・セミナー・シンポジウム
- 「四次元放射線治療」,東北大学がんプロ,中村光宏
- 「呼吸性移動に対するアプローチ」,放射線治療品質管理機構認定研究会 東北ラジセラ研究会,中村光宏
- 「Vero4DRT (MHI-TM2000)」,日本放射線腫瘍学会 第25回学術大会,中村光宏
- 「高精度放射線治療のガイドラインを理解する (呼吸性移動対策ガイドライン)」,日本医学物理士会,中村光宏
- 「Heliosの操作説明,段階的な最適化の進め方」,第22回京大病院高精度放射線治療ワークショップ,中村光宏
- 「呼吸同期照射」,滋賀県放射線治療連絡協議会,中村光宏
- 「入門講座: 呼吸同期照射」,日本放射線技術学会,中村光宏
- 「Heliosの操作説明,段階的な最適化の進め方」,第20回京大病院高精度放射線治療ワークショップ,中村光宏
- 「放射線治療計画の品質保証・品質管理-その計画思った通りですか?-」,第111回放射線治療かたろう会,宮部結城
- 「4次元放射線治療:動体への対応」,第1回JASTRO放射線治療物理学セミナー,宮部結城
- 「MIM Maestroを用いた4次元線量評価」,第1回 MIM Maestroユーザーズミーティング,宮部結城
受賞
- 第103回日本医学物理学会学術大会 大会長賞優秀発表賞,椋本 宜学
- World Congress 2012 Young Investigator Composition 3rd Prize, 石原 佳知
研究費
公的研究費の受入状況
その他の研究費の受入状況
- 平成24年度 医学物理学会研究助成 「強度変調放射線治療における線量検証の標準化に向けた調査研究」,中村光宏 (代表)
- 平成24年度 医学物理士研究活動助成 「前立腺癌IMRTの高精度化に関するCBCT画像を利用した後方視的研究」,中村光宏 (代表)
- 平成24年度 医用原子力技術に関する研究助成 「動体追尾照射におけるQA/QCプロトコールの確立」,椋本宜学 (代表)